JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online February 17, 2009, 10.2967/jnmt.108.054296
doi:10.2967/jnmt.108.054296
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow All Versions of this Article:
jnmt.108.054296v1
37/1/38    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Razifar, P.
Right arrow Articles by Långström, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Razifar, P.
Right arrow Articles by Långström, B.
Journal of Nuclear Medicine Technology Volume 37, Number 1, 2009 38-44
© 2009 by Society of Nuclear Medicine

An Automated Method for Delineating a Reference Region Using Masked Volumewise Principal-Component Analysis in 11C-PIB PET

Pasha Razifar1,2, Henry Engler3, Anna Ringheim4, Sergio Estrada4, Anders Wall4 and Bengt Långström4,5

1 Michigan and CT Research, GE Healthcare, Waukesha, Wisconsin, 2 Uppsala Applied Science Lab, GE Healthcare, Uppsala, Sweden, 3 Department of Medical Science, Uppsala University, Uppsala, Sweden, 4 Uppsala Imanet, GE Healthcare, Uppsala, Sweden, 5 Department of Biochemistry and Organic Chemistry, Uppsala University, Uppsala, Sweden

Correspondence: For correspondence or reprints contact: Pasha Razifar, Uppsala Applied Science Lab (UASL), GE Healthcare, GEMS PET Systems AB, Husbyborg, SE-752 28 Uppsala, Sweden. E-mail: pasha.razifar{at}ge.com

Kinetic modeling using a reference region is a common method for the analysis of dynamic PET studies. Available methods for outlining regions of interest representing reference regions are usually time-consuming and difficult and tend to be subjective; therefore, MRI is used to help physicians and experts to define regions of interest with higher precision. The current work introduces a fast and automated method to delineate the reference region of images obtained from an N-methyl-11C-2-(4'-methylaminophenyl)-6-hydroxy-benzothiazole (11C-PIB) PET study on Alzheimer disease patients and healthy controls using a newly introduced masked volumewise principal-component analysis. Methods: The analysis was performed on PET studies from 22 Alzheimer disease patients (baseline, follow-up, and test/retest studies) and 4 healthy controls, that is, a total of 26 individual scans. The second principal-component images, which illustrate the kinetic behavior of the tracer in gray matter of the cerebellar cortex, were used as input data for automatic delineation of the reference region. To study the variation associated with the manual and proposed automatic methods, we defined the reference region repeatedly. Results: As expected, the automatic method showed no variation whereas the manual method varied significantly on repetition. Furthermore, the automatic method was significantly faster, more robust, and less biased. Conclusion: The automatic method is helpful in the delineation of the reference region of 11C-PIB PET studies of the human brain and is much faster and more precise than manual delineation.

Key Words: positron emission tomography; masked volumewise principal-component analysis; automatic delineation; reference region; Alzheimer disease







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
THE JOURNAL OF NUCLEAR MEDICINE JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY
Copyright © 2009 by the Society of Nuclear Medicine Technologist Section.