JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online August 14, 2008, 10.2967/jnmt.108.052555
doi:10.2967/jnmt.108.052555
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnmt.108.052555v1
36/3/147    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Belakhlef, S.
Right arrow Articles by Lakhanpal, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Belakhlef, S.
Right arrow Articles by Lakhanpal, S.
Journal of Nuclear Medicine Technology Volume 36, Number 3, 2008 147-150
© 2008 by Society of Nuclear Medicine

Quantitative Assessment of the Influence of Location, Internal Temperature, Idle Time, and Normalization on the Sensitivity of a Mobile PET/CT Scanner

Sam Belakhlef, Cliff Church, Allison Hays, Ron Fraser and Suresh Lakhanpal

Phoebe Putney Memorial Hospital, Albany, Georgia

Correspondence: For correspondence or reprints contact: Sam Belakhlef, Phoebe Putney Memorial Hospital 417, Third Ave., P.O. Box 1828, Albany, GA 31702-1828. E-mail: sbelakhl{at}ppmh.org

The superiority of PET/CT and 18F-FDG imaging in cancer assessment has created the need in rural community hospitals to acquire this technology. However, high cost and lack of patient volume have prohibited these institutions from attaining in-house scanners. By using mobile PET/CT scanners, small rural hospitals are able to deliver this valuable clinical tool to their patients. As mobile PET/CT scanners are shifted from one site to another, however, they are exposed to harsher and frequently varying ecologic conditions that can alter their performance. Because of the importance of the standardized uptake value in cancer evaluation and its linear relationship to the sensitivity of the scanner, we investigated conditions affecting the sensitivity of the mobile PET/CT scanner. Methods: We used a 68Ge cylindric phantom with 2 bed frames scanned for 3 min each to simulate a patient to assess quantitatively the influence of location, increase in scanner internal temperature, idle time, and normalization on the sensitivity of the mobile PET/CT scanner. The raw phantom data were acquired and reconstructed with the parameters used for oncology patients. The scanner sensitivity values (Bq/mL) were obtained from circular regions of interest drawn on the phantom images. These values were compared with the true phantom activity concentration after it was decay-corrected to the specific scanning day. Results: The average sensitivity errors (mean ± SD) of this mobile PET/CT scanner at sites 1–4 were 1.84% ± 0.98%, 2.43% ± 2.05%, 2.08% ± 0.91%, and 4.34% ± 1.93%, respectively. A 41.17% increase in the scanner internal temperature decreased its sensitivity by an average of 16.09% ± 3.58%. After day 1 and day 2, its average sensitivity errors were 3.27% ± 0.01% and 2.65% ± 0.02%, respectively. Before and after normalization, the average sensitivity errors were 3.06% ± 1.37% and 2.69% ± 1.69%, respectively. Conclusion: Temperature and normalization affected the sensitivity of the scanner the most and should be monitored closely, with normalization performed as recommended by the manufacturer.

Key Words: instrumentation; molecular imaging; PET/CT; quality assurance; mobile PET/CT sensitivity; parameters affecting sensitivity