JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online August 16, 2007, 10.2967/jnmt.106.038992
doi:10.2967/jnmt.106.038992
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnmt.106.038992v1
35/3/154    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mroczenski, A. A.
Right arrow Articles by Mullan, B. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mroczenski, A. A.
Right arrow Articles by Mullan, B. P.
Journal of Nuclear Medicine Technology Volume 35, Number 3, 2007 154-158
© 2007 by Society of Nuclear Medicine

Trends of Radiopharmaceutical Use at Mayo Clinic Rochester

Ashley A. Mroczenski, Stephanie M. Berent, Alice A. Hall, Joseph C. Hung, Thomas J. Herold and Brian P. Mullan

Department of Radiology, Mayo Clinic, Rochester, Minnesota

Correspondence: For correspondence contact: Joseph C. Hung, PhD, Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905. E-mail: jhung{at}mayo.edu

The field of radiology is continuously changing. The purpose of this study was to identify the effect of technologic advances on nuclear medicine during the past 15 y. Methods: The number of radiopharmaceutical doses dispensed at Mayo Clinic (Rochester, Minnesota) from 1990 through 2004 was tracked. The number of doses was equivalent to the number of scans performed. Results: Since 1990, the number of bone scans decreased by 38%. Brain scans using 99mTc have increased by 166%. The number of cardiac doses dispensed increased 184% from 1990 through 1999 but decreased 3% between 2000 and 2004. The number of lung scans decreased 52% from 1992 through 1999 and increased 66% from 1999 through 2004. The number of kidney scans decreased 67% since 1990. Since its introduction in 1993, the use of 111In-pentetreotide has increased 16-fold. PET data showed a 602% increase in the number of procedures from 2001 through 2004. Conclusion: The number of bone, lung, and kidney scans has decreased because of advances in other imaging modalities. Although the number of cardiac imaging scans increased during most of the study period, the recent rate of growth has declined, possibly because of the availability of alternative procedures such as stress echocardiography. The number of brain and lung scans performed has increased, partially because of the development of new protocols. PET and tumor imaging have shown a substantial increase because of increasing numbers of approved indications and Medicare reimbursement.

Key Words: nuclear pharmacy; radiopharmaceuticals; use trends







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
THE JOURNAL OF NUCLEAR MEDICINE JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY
Copyright © 2007 by the Society of Nuclear Medicine Technologist Section.