JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online May 11, 2007, 10.2967/jnmt.106.037044
doi:10.2967/jnmt.106.037044
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnmt.106.037044v1
35/2/105    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Currie, G. M.
Right arrow Articles by Wheat, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Currie, G. M.
Right arrow Articles by Wheat, J. M.
Journal of Nuclear Medicine Technology Volume 35, Number 2, 2007 105-111
© 2007 by Society of Nuclear Medicine

Improved Detection and Localization of Lower Gastrointestinal Hemorrhage Using Subtraction Scintigraphy: Clinical Evaluation

Geoffrey M. Currie, CNMT, Philip A. Towers and Janelle M. Wheat

School of Biomedical Sciences, Charles Sturt University, Wagga Wagga, Australia

Correspondence: For correspondence or reprints contact: Geoffrey M. Currie, PhD, CNMT, School of Biomedical Sciences, Locked Bag 588, Charles Sturt University, Wagga Wagga 2678, Australia. E-mail: gcurrie{at}csu.edu.au

Does subtraction scintigraphy improve the diagnostic utility of scintigraphic evaluation in acute lower gastrointestinal hemorrhage? Methods: This research was a retrospective clinical study using a repeat-measures design of randomized control and experimental groups. A single patient dataset provided both the control group (conventional scintigraphy) and the experimental group (conventional and subtraction techniques). Forty-nine raw 99mTc-red blood cell studies were randomized and interpreted by 4 independent physicians as conventional scintigraphy data only (round 1). The conventional scintigraphy studies were combined with subtraction images and randomized for reinterpretation (round 2). Results: Although there was a decrease in the mean, no statistically significant difference was noted between the mean time to bleed detection between interpretive rounds 1 and 2 (P = 0.524). The addition of subtraction scintigraphy to the interpretation process changed the outcome from "probably present" to "absent" for 14% of patients and from "equivocal" to "absent" for another 12%, and this change had a marked effect on the false-positive rate. The false-positive rate decreased from 9.6% in round 1 to 3.6% in round 2. Receiver operator characteristic analysis showed that combining conventional scintigraphy with subtraction scintigraphy improved test performance. Conclusion: False-positive studies can be reduced by using subtraction scintigraphy in conjunction with conventional scintigraphy in the interpretive process.

Key Words: bowel hemorrhage; gastrointestinal tract bleeding; subtraction scintigraphy; localization; lower gastrointestinal hemorrhage







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
THE JOURNAL OF NUCLEAR MEDICINE JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY
Copyright © 2007 by the Society of Nuclear Medicine Technologist Section.