JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsopelas, C.
Right arrow Articles by Blefari, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsopelas, C.
Right arrow Articles by Blefari, C.
Journal of Nuclear Medicine Technology Volume 31, Number 1, 2003 37-40
© 2003 by Society of Nuclear Medicine


RADIATION SAFETY

A Simple and Effective Technique to Reduce Staff Exposure During the Preparation of Radiopharmaceuticals

Chris Tsopelas, PhD1, Peter J. Collins, MSc2 and Cristina Blefari, BMRad2

1RAH Radiopharmacy, Royal Adelaide Hospital, Adelaide, South Australia, Australia;
2Nuclear Medicine Department, Royal Adelaide Hospital, Adelaide, South Australia, Australia

ABSTRACT

Objective:In the preparation of radiopharmaceuticals, staff receive considerable radiation exposure to the hands during withdrawal of activity from the elution vial, from a combination of the syringe and elution vial activities. In an attempt to reduce the radiation burden to the hands, a simple technique was developed that utilizes a modified lead pot lid and a syringe bearing a long needle with a sterile needle guide.

Methods:An elution vial in a lead pot with an attached syringe was secured at an angle of 45°, simulating the action of withdrawing 99mTc-pertechnetate from the elution vial. The 99mTc activity ratio of vial to syringe was 20:1. A gamma- camera detector without collimator was positioned at the syringe plunger and count profiles were obtained after 10 min of data acquisition. The experiment was repeated using the same set-up with (a) the modified lid on the lead pot and (b) a cold syringe to determine the contribution of the radioactive syringe to the count profile. Each experiment was repeated at the vertical position, simulating the normal action of redispensing 99mTc activity into the elution vial.

Results:The modified lid reduced exposure from the elution vial, with a count reduction of >98% for both orientations. The contributions of vial radioactivity to the total count profile were 76% and 84% for vertical and 45° orientations, respectively. The contributions of syringe activity were 24% and 16% for vertical and 45° orientations, respectively.

Conclusion:A reduction in the photon flux to the hands of up to 84% (with an associated reduction in hand dose) can be achieved by withdrawing activity through a modified lid on the lead pot housing the elution vial, without significantly altering normal work practices.

Key Words: radiopharmaceutical procedures; staff radiation exposure; radiation protection




This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
S. G. P. Cecatti and L. V. E. Caldas
Preliminary dosimetric characterisation of thermoluminescent materials for beta radiation monitoring at nuclear medicine services
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 307 - 311.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
THE JOURNAL OF NUCLEAR MEDICINE JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY
Copyright © 2003 by the Society of Nuclear Medicine Technologist Section.