JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leong, L. K.
Right arrow Articles by O’Connor, M. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leong, L. K.
Right arrow Articles by O’Connor, M. K.
Journal of Nuclear Medicine Technology Volume 29, Number 2, 2001 79-83
© 2001 by Society of Nuclear Medicine


IMAGING

A Comparison of the Uniformity Requirements for SPECT Image Reconstruction Using FBP and OSEM Techniques

Lai K. Leong, Randall L. Kruger and Michael K. O’Connor

Section of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, Minnesota

Objective: Gamma camera nonuniformity can result in the presence of ring artifacts in reconstructed SPECT images. The objective of this study is to compare the relationship between ring artifact magnitude and image noise in tomographic images reconstructed using FBP and OSEM.

Methods: A cylindrical phantom was filled with water and 99mTc. Seven tomographic acquisitions were performed, with total counts per acquisition ranging from 1.5 Mcts to 100 Mcts. All acquisitions were reconstructed using both FBP and OSEM. Ring artifacts were generated in the transaxial data by introducing defects at a given location in each planar image. The modified acquisitions were again reconstructed using both FBP and OSEM. The ring artifacts were isolated by the subtraction of the uncorrupted datasets from the corrupted datasets. The magnitude of the ring artifacts in the corrupted reconstructions was measured and compared to the mean counts and noise level in the uncorrupted data.

Results: Ring magnitude in OSEM-reconstructed images is approximately one third that of FBP images. However, there is a corresponding reduction in image noise with OSEM and the ratio of ring magnitude-to-image noise was relatively similar for both OSEM and FBP. Rings generated with OSEM fell off more rapidly with distance from the image center, and reached a plateau at a higher magnitude at large distances. The visibility of rings with OSEM relative to FBP will depend on the location of the causative defect in the planar data and the number of iterations performed with OSEM. Differences between the 2 algorithms are subtle.

Conclusion: Our results would indicate that the uniformity requirements for SPECT are similar for FBP and OSEM reconstruction algorithms.

Key Words: SPECT; FBP; OSEM; ring artifacts; uniformity




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
A. Massaro, S. Cittadin, F. Rossi, L. Rampin, E. Banti, O. Nibale, and D. Rubello
Reconstruction Parameters for 111In-Pentetreotide SPECT: Variability with Respect to Body Weight and Body Region
J. Nucl. Med. Technol., December 1, 2007; 35(4): 237 - 241.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
A. Seret and F. Bleeser
Intrinsic Uniformity Requirements for Pinhole SPECT.
J. Nucl. Med. Technol., March 1, 2006; 34(1): 43 - 47.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
H. Kizu, T. Takayama, M. Fukuda, M. Egawa, H. Tsushima, M. Yamada, K. Ichiyanagi, K. Yokoyama, M. Onoguchi, and N. Tonami
Fusion of SPECT and Multidetector CT Images for Accurate Localization of Pelvic Sentinel Lymph Nodes in Prostate Cancer Patients
J. Nucl. Med. Technol., June 1, 2005; 33(2): 78 - 82.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
THE JOURNAL OF NUCLEAR MEDICINE JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY
Copyright © 2001 by the Society of Nuclear Medicine Technologist Section.