JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Patel, M.
Right arrow Articles by al-Bunny, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Patel, M.
Right arrow Articles by al-Bunny, A.

Journal of Nuclear Medicine Technology, Vol 26, Issue 4 269-273, Copyright © 1998 by Society of Nuclear Medicine


ARTICLES

Modified preparation and rapid quality control test for technetium-99m-tetrofosmin

M Patel, A Owunwanne, M Tuli, K al-Za'abi, S al-Mohannadi, M Sa'ad, S Jahan, A Jacob and A al-Bunny
Department of Nuclear Medicine, Kuwait Cancer Control Center, Kuwait City.

OBJECTIVE: The objectives of this study were to: modify the preparation of 99mTc-tetrofosmin by using twice the amount of 99mTcO4- recommended by the manufacturer; evaluate the use of miniaturized rapid paper chromatography (MRPC) for quality control (QC) testing; and determine the in vitro stability of the modified preparation using MRPC. METHODS: Two preparations of 99mTc-tetrofosmin were made: one with 4.4-8.8 GBq (120-240 mCi) and the other with 13.9-17.6 GBq (380-480 mCi) 99mTcO4-, referred to as regular and modified preparations, respectively. Routine QC tests were performed using MRPC and instant thin-layer chromatography/silica-gel (ITLC/SG) systems. The preparations were injected into 58 patients. Planar and SPECT images of stress and rest studies were obtained. The technical quality of the SPECT images was graded visually by four observers. Heart-to-lung and heart-to-background ratios were calculated from the planar images. RESULTS: The QC testing procedure took 4.18 +/- 0.15 min with MRPC and 54 +/- 5.3 min with ITLC/SG systems. The percent labeling efficiency, as determined by both techniques, ranged from 95.6 +/- 1.6 to 97.2% +/- 0.8%. Both preparations were stable up to 6 hr after reconstitution. There was no difference between the cardiac-to-lung and cardiac-to-background ratios of the two preparations. CONCLUSION: The results indicate that MRPC is a faster and effective chromatographic technique for routine QC testing of 99mTc-tetrofosmin. Doubling the amount of 99mTcO4- used in preparing 99mTc-tetrofosmin did not affect its in vitro stability, its efficacious use in patients or the technical quality of the images.