JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Amin, K. C.
Right arrow Articles by Go, R. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Amin, K. C.
Right arrow Articles by Go, R. T.

Journal of Nuclear Medicine Technology, Vol 25, Issue 1 49-51, Copyright © 1997 by Society of Nuclear Medicine


ARTICLES

A rapid chromatographic method for quality control of technetium-99m-bicisate

KC Amin, GB Saha and RT Go
Department of Nuclear Medicine, Cleveland Clinic Foundation, OH 44195, USA.

The purpose of this work was to develop a simple and rapid method to determine the radiochemical purity of 99mTc-bicisate. METHODS: A rapid paper chromatographic (PC) method was developed to determine the radiochemical purity of 99mTc-bicisate and compare the results with those of the manufacturer's recommended method. The present PC method included Whatman 3MM paper as the solid phase and ethyl acetate as the solvent. RESULTS: The time for chromatography by this technique was 4-5 min compared to about 23 min by the manufacturer's method. The Rf value of 99mTc-bicisate (Rf = 0.9-1.0) was widely different from those of 99mTcO4- and reduced 99mTc (Rf = 0.0 for both) so the chromatographic strip after development could be readily cut into two segments, in order to determine the labeling yield. CONCLUSION: No significant difference in labeling yields was found between the present method and the manufacturer's method. The PC method using Whatman 3MM paper and ethyl acetate is a simple and fast technique to determine the radiochemical purity of 99mTc-bicisate and may be substituted for the manufacturer's recommended method to save time.


This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
C. Tsopelas and D. Smyth
Characterization and Quality Control Analysis of 99mTc-Bicisate
J. Nucl. Med. Technol., June 1, 2005; 33(2): 89 - 93.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
THE JOURNAL OF NUCLEAR MEDICINE JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY
Copyright © 1997 by the Society of Nuclear Medicine Technologist Section.