JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stallings, L. E.
Right arrow Articles by Humphries, J. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stallings, L. E.
Right arrow Articles by Humphries, J. K.

Journal of Nuclear Medicine Technology, Vol 25, Issue 1 44-48, Copyright © 1997 by Society of Nuclear Medicine


ARTICLES

Ultratag RBC kit for combined cardiac first-pass and multigated acquisition studies

LE Stallings, KT Cheng, KM Spicer, R Wiegner and JK Humphries
Department of Nuclear Medicine, Medical University of South Carolina, Charleston 29425, USA.

The authors developed a procedure to use the in vitro Ultratag (Mallinckrodt, St. Louis, MO) red blood cell (RBC) labeling kit for both first-pass (FP) and multigated acquisition (MUGA) studies with a high specific activity in a reduced volume (50 mCi/0.5 ml) and a high labeling efficiency that can be used with a single-crystal camera to yield a quality study. METHODS: A packed red blood cell (PRBC) bolus was created by two methods: (a) reducing the volume of the components of the Ultratag kit and (b) centrifuging the final dose volume. The labeling efficiency of each bolus was evaluated, each PRBC bolus was visually inspected for clots and percent hemolysis was assessed using a hemocytometer at 30 min, 1 hr and 2 hr postcentrifugation. RESULTS: Use of the first method, the 50% kit, provided the best results. However, the resulting volume from this kit only approached 1 ml, which is not clinically adequate for a first-pass study. In the second method, the total volume was centrifuged to form a PRBC bolus, which appeared to be stable in the syringe for at least 2 hr. A combined FP/MUGA study from a centrifuged 50% reduced kit was performed in one normal subject as a preliminary assessment of the clinical utility of this procedure. The image quality of the scan is diagnostically adequate. CONCLUSION: By using the in vitro Ultratag kit, a compact PRBC bolus was created that was stable in the syringe and could be reinjected safely into the patient for combined cardiac FP/MUGA studies.