Click on image to view larger version.


Figure 4


FIGURE 4.  How indicator dilution technique is used to measure blood volume. Known quantity of tracer is administered (A), time is allowed for complete mixing (B), and blood sample is drawn for counting (C). Typical nuclear tracers are 51Cr-labeled erythrocytes (RBCs) and 125I-HSA.